Elastomer-based compound can be moisture cured with the addition of a catalyst masterbatch (Sioplas method). It is a cable compound for insulation and jacketing.
Cable insulation with a proper mixture of KKX-420G (95 parts) and CAT-XL (5 parts) ex hibits excellent thermo- oxidative stability.
KKX-420G / CAT-XL in combination meets the applicable requirements as below when processed using sound extrusion and testing procedure:
EN 50363-1 EI7 and EI8
EN 50363-0 G7; ; IEC 60502 EPR and HEPR
EN 50363-2 EM6, IEC 60502-1
BS 7655 GP4, GP5, GP6 and GP7;
EN 60092/360 EPR and HEPR Cenelec HD 603 DIH1, DIH2 and DIH3; VDE 0207/20 3GI3
KKX-423/CAT-XL silane crosslinkable natural compound system designed for insulation of low voltage energy cables. KKX-423 / CAT-XL is designed for Insulation of low voltage energy cables, range up to 6 kV.
KKX-423 is a low density polyethylene, copolymerised with vinyl silane. CAT-XL is an ambient crosslinking catalyst masterbatch specially designed to be used. The system is highly active and crosslinks quickly at in sauna or in hot water.
The proper mixture could be;
• 95% for KKX-423 (base polymer), 5% for CAT-XL (catalyst)
• 93% for KKX-423 (base polymer), 7% for CAT-XLB (black catalyst)
Crosslinking by immersion in 90°C hot water 2-6 hours; by exposure to low pressure water steam, 12-15 hours. It cures after 72 hours at room conditions.
Properties of this compound comply with the requirements of,
ASTM D 1248 Type I, Class A, Category 4
HD 603 S1
HD 604 S1, NEMA WC 70, IEC 60502-1
UL94
KKX-MXLPE/CAT-XL is a silane crosslinkable medium density polyethylene natural compound system designed for insulation of low voltage energy cables.
KKX-MXLPE is a medium density polyethylene, copolymerised with vinyl silane. CAT-XL is an ambient crosslinking catalyst masterbatch specially designed to be used. The system is highly active and crosslinks quickly at in sauna or in hot water.
Cable insulation with a proper mixture of KKX-MXLPE (95 parts) and CAT-XL (5 parts) exhibits excellent thermo-oxidative stability. The combination is suitable for both copper and aluminum conductors.
Crosslinking by immersion in 90°C hot water 2-6 hours; by exposure to low pressure water steam, 12-15 hours. It cures after 72 hours at room conditions.
KKX-MXLPE / CAT-XL in combination meets the applicable requirements as below when processed using sound extrusion and testing procedure:
IEC 60092/360; IEC 60502 XLPE
VDE 0276 2XI1; HD 604 2XI1
BS 7655 GP8; HD 626 S1, TX3, TX5 and TX8
NF C33-209
KKX-XLPE1/CAT-XL is a silane crosslinkable natural compound system designed for insulation of low voltage energy cables. KKX-XLPE1 / CAT-XL is designed for Insulation of low voltage energy cables, range up to 6 kV.
KKX-XLPE1 is a low density polyethylene, copolymerised with vinyl silane. CAT-XL is an ambient crosslinking catalyst masterbatch specially designed to be used. The system is highly active and crosslinks quickly at in sauna or in hot water.
The combination is suitable for both copper and aluminum conductors. If the insulation is designed to meet the thermo-oxidative ageing demand required by IEC 60502 at 150°C in contact with copper, the addition of 9 parts KKX-XLPE1 to CAT-XL is recommended.
The proper mixture could be;
• 95% for KKX-XLPE1 (base polymer), 5% for CAT-XL (catalyst)
• 93% for KKX-XLPE1 (base polymer), 7% for CAT-XLB (black catalyst)
Crosslinking by immersion in 90°C hot water 2-6 hours; by exposure to low pressure water steam, 12-15 hours.
KKX-XLPE1 / CAT-XL in combination meets the applicable requirements as below when processed using sound extrusion and testing procedure:
ASTM D 1248 Type I, Class A, Category 4
HD 603 S1
HD 604 S1, IEC 60502-1
NEMA WC 70/ ICEA S-100-685
NEMA WC 71/ ICEA S-96-659
EN 50290-2-29
Product Information:
Elastomer-based compound can be moisture cured with the addition of a catalyst masterbatch (Sioplas method). It is a cable compound for insulation and jacketing.
Cable insulation with a proper mixture of KKX-430G (95 parts) and CAT-XL (5 parts) ex hibits excellent thermo- oxidative stability.
KKX-430G / CAT-XL in combination meets the applicable requirements as below when processed using sound extrusion and testing procedure:
IEC 60502 EPR; VDE 0207/20 3GI3
N 50363-1 EI3 EI4 EI6 and EI7
EN 50363-2 EM3, EM4 and EM6
BS 7655 RS5 and GP7
EN 60092/360 EPR
and DIH3; VDE 0207/20 3GI3
MSDS REQUEST
Product Information:
KKX-HXLPE/CAT-XL is a silane crosslinkable high density polyethylene natural compound system designed for insulation of low voltage energy cables.
KKX-HXLPE is a high density polyethylene, copolymerised with vinyl silane. CAT-XL is an ambient crosslinking catalyst masterbatch specially designed to be used. The system is highly active and crosslinks quickly at in sauna or in hot water.
Cable insulation with a proper mixture of KKX-HXLPE (95 parts) and CAT-XL (5 parts) exhibits excellent thermo-oxidative stability. The combination is suitable for both copper and aluminum conductors.
Crosslinking by immersion in 90°C hot water 2-6 hours; by exposure to low pressure water steam, 12-15 hours. It cures after 72 hours at room conditions.
KKX-HXLPE / CAT-XL in combination meets the applicable requirements as below when processed using sound extrusion and testing procedure:
IEC 60092/360; IEC 60502 XLPE
BS 7655 GP8; HD 626 S1, TX3, TX5 and TX8
VDE 0276 2XI1; HD 604 2XI1
Product Information:
KKX-XLPE/CAT-XL is a silane crosslinkable natural compound system designed for insulation of low voltage energy cables. KKX-XLPE / CAT-XL is designed for Insulation of low voltage energy cables, range up to 6 kV.
KKX-XLPE is a low density polyethylene, copolymerised with vinyl silane. CAT-XL is an ambient crosslinking catalyst masterbatch specially designed to be used. The system is highly active and crosslinks quickly at in sauna or in hot water.
Cable insulation with a proper mixture of KKX-XLPE (95 parts) and CAT-XL (5 parts) exhibits excellent thermo-oxidative stability. The combination is suitable for both copper and aluminum conductors. If the insulation is designed to meet the thermo-oxidative ageing demand required by IEC 60502 at 150°C in contact with copper, the addition of 9 parts KKX-XLPE to CAT-XL is recommended.
Crosslinking by immersion in 90°C hot water 2-6 hours; by exposure to low pressure water steam, 12-15 hours.
KKX-XLPE / CAT-XL in combination meets the applicable requirements as below when processed using sound extrusion and testing procedure:
ASTM D 1248 Type I, Class A, Category 4
HD 603 S1
HD 604 S1, IEC 60502
NEMA WC 70/ ICEA S-100-685
NEMA WC 71/ ICEA S-96-659
EN 50290-2-29
MSDS REQUEST
Adding {{itemName}} to cart
Added {{itemName}} to cart